software:vmware:vmware-smart

VMware и SMART

Подключаемся по SSH к серверу

Смотрим перечень дисков и их UID:

 # esxcli storage core device list | egrep 'Model|UID'
   Model: ST2000DM001-1CH1
   Other UIDs: vml.0100000000202020202020202020202020573145314858534b535432303030

Смотрим диск:

# esxcli storage core device smart get -d vml.0100000000202020202020202020202020573145314858534b5354
32303030
Parameter                     Value  Threshold  Worst
----------------------------  -----  ---------  -----
Health Status                 OK     N/A        N/A
Media Wearout Indicator       N/A    N/A        N/A
Write Error Count             N/A    N/A        N/A
Read Error Count              120    6          99
Power-on Hours                92     0          92
Power Cycle Count             100    20         100
Reallocated Sector Count      100    36         100
Raw Read Error Rate           120    6          99
Drive Temperature             26     0          40
Driver Rated Max Temperature  74     45         61
Write Sectors TOT Count       200    0          200
Read Sectors TOT Count        N/A    N/A        N/A
Initial Bad Block Count       100    99         100
# ./usr/lib/vmware/vm-support/bin/smartinfo.sh